Power Measurement & Power Quality E-MON PowerSmart Advanced Power Quality Meter

E-MON PowerSmart Advanced Power Quality Meter

E-MON PowerSmart Advanced Power Quality Meter
E-MON PowerSmart Advanced Power Quality Meter
Brand: E-MON
Product Code: E-MON PowerSmart Advanced Power Quality Meter
Availability: 2-4 Weeks

All products ship from Toronto, Canada by courier. Shipping is usually 1-10 days depending on your location in Canada. Shipping is free of charge. Orders received before 2:00pm (Mon-Fri) will be shipped on the same day (provided item is available in stock). 

You can pay with all major credit cards. On our side, we use PayPal to process all credit card transactions. But on your side, it will be like any regular purchase. You do not need to create a PayPal account. From the shopping cart, simply select "PayPal / Credit Card", then select "Pay with a credit or Visa debit card".

Customer satisfaction guaranteed, or your money back. RCC Electronics is proudly Canadian. We have been selling the best test equipment since 1978.

 

Overview

  • The PowerSmart+ Advanced power quality meter is a multi-function power meter combined with a power quality analyzer. The meter has extensive memory and data logging capability to support full harmonic analysis and waveform recording. The device can be integrated into panel boards or provided in a stand-alone enclosure. Flexible communication options include RS-485 and Ethernet for remote visualization. The PowerSmart+ Advanced meter is ideal for power quality analysis & recording of harmonics, spikes, sags, swell, etc. of specific critical loads to an entire building.


• Easy to read 3-row bright LED display, adjustable update time, auto-scroll option with adjustable page exposition time and auto-return to a default page.

• LED bar graph showing percent load with respect to user-definable nominal load current.

• Supplied with E-Mon Power Software for meter set up and power quality analysis.

• Ampere/Volt/THD/TDD demand meter with advanced power quality features including embedded harmonic analyzer, voltage and current THD, current TDD and K-Factor, inter-harmonics THD, up to the 50th order harmonic.

• 3 voltage and 3 current transformer-isolated AC inputs for direct connection to power line or via potential and current transformers.

• Voltage and current harmonic spectrum and angles.

• Current Sensor Options:
- Available with integrated 5 Amp current sensors for use with existing 5 Amp current sensors for use with existing 5 Amp output current transformers
- Available as a meter only configuration for use with PowerSmart current sensors. Current sensor leads can be extended up to 500 feet for remote installation (sold separately, see PowerSmart current sensors for more details.)

• Standard 2-wire RS-485 communication port; Modbus RTU, DNP3 and ASCII communication protocols.

• Optional Ethernet 10/100BaseT port for Modbus TCP/IP communication.

• Two digital inputs for monitoring external contacts, and receiving pulses from energy, water and gas meters. Two relay outputs for alarms and controls, and for output of energy pulses.

• Optionally available pre-installed inside a JIC steel enclosure with lockable window panel and 3-phase voltage terminal block. Dimensions: 14" H x 12" W x 8" D.

• Time of Use (TOU), 8 totalization and tariff energy/demand registers x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day, easy programmable tariff schedule.

• Automatic daily profile for energy and maximum demand readings (total and tariff registers.)

• Embedded programmable controller; 16 control setpoints; programmable thresholds and delays; relay output control; 1/2 cycle response time.

• Event recorder for logging and internal diagnostics events, control events and I/O operations. 16 data recorders; programmable data logs on a periodic basis and on any internal and external trigger.

• Two waveform recorders; simultaneous 6-channel AC recording in a single plot; sampling rate of 32, 64 and 128 samples per cycle; 20 pre-fault cycles; up to 30 seconds of continuous recording at a rate of 32 samples per cycle.

• EN50160 Power Quality recorder (EN50160 compliance statistics, EN50160 harmonics survey statistics, onboard power quality analyzer; programmable thresholds and hysteresis; ready for use reports.)

• Real-time waveform capture and monitoring; simultaneous 6-channel 4-cycle capture at 128 samples per cycle.

    • Electric Submeter Features
    •  
    •  

    • • Class 0.2 four-quadrant multi-function 3-phase energy meter (tru RMS, volts, amps, power, power factor, neutral current, voltage and current unbalance and frequency.)
    •  
    •  

 