All products ship from Toronto, Canada by courier. Shipping is usually 1-10 days depending on your location in Canada. Shipping is free of charge. Orders received before 2:00pm (Mon-Fri) will be shipped on the same day (provided item is available in stock). You can pay with all major credit cards. On our side, we use PayPal to process all credit card transactions. But on your side, it will be like any regular purchase. You do not need to create a PayPal account. From the shopping cart, simply select "PayPal / Credit Card", then select "Pay with a credit or Visa debit card". Customer satisfaction guaranteed, or your money back. RCC Electronics is proudly Canadian. We have been selling the best test equipment since 1978. |
Basic specifications
Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
DC Voltage | 400.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±3 dgt. |
---|---|
AC Voltage 40 to 500 Hz |
400.0 mV to 1000 V, 5 ranges, Frequency characteristics: 40 Hz - 500 Hz Basic accuracy: ±1.0 % rdg. ±5 dgt. (True RMS, crest factor 2 to 1.5) |
Resistance | 400.0 Ω to 40.00 MΩ, 6 ranges, Basic accuracy: ±0.5 % rdg. ±2 dgt. |
DC Current | 400.0 μA to 10.00 A, 6 ranges, Basic accuracy: ±1.2 % rdg. ±3 dgt. |
AC Current, 40 to 500 Hz |
400.0 μV to 10.00 A, 6 ranges, Frequency characteristics: 40 Hz - 500 Hz Basic accuracy: ±1.2 % rdg. ±5 dgt. (True RMS, crest factor 2 to 1.5) |
Temperature (use with DT4910) | K: -55.0 to 400.0 °C, 400 to 700 °C, Add the Temperature probe accuracy to Basic accuracy: ±2.0 % rdg. ±1 °C |
Voltage Detection | N/A |
C (capacitance) | 50.00 nF to 100.0 μF, 5 ranges, Basic accuracy: ±2.0 % rdg. ±5 dgt. |
Frequency |
AC V measurement: 5.000 Hz (1 Hz or more) to 5.000 MHz, 7 ranges, Basic accuracy: ±0.1 % rdg. ±3 dgt. Minimum sensitivity voltage: Square wave of 1.5 Vrms |
Continuity Check | Continuity threshold [ON]: 90 Ω ±40 Ω or less (Buzzer sound) |
Diode test | Open terminal voltage: 3.0 V or less, Testing current 0.5 mA |
Environment | Operating temperature: -10 to 50 °C, Storage temperature: -20 to 60 °C |
Other functions | Display value hold, Relative display, Auto-power off, Back light |
Display | 4-digits LCD, max. 4000 counts |
Display refresh rates | 3 times/s |
Power supply |
LR6 alkaline batteries ×2, R6P manganese batteries ×2, Continuous use: 800 hours (When using alkaline batteries) |
Dimensions and mass | 91.6 mm (3.61 in)W × 180.6 mm (7.11 in)H× 57.1 mm (2.25 in)D, 388 g (13.7 oz) (including batteries and holster) |
Accessories | Test Lead L9206 ×1, holster (attached) ×1, instruction manual ×1, R6P manganese battery ×2 |