All products ship from Toronto, Canada by courier. Shipping is usually 1-10 days depending on your location in Canada. Shipping is free of charge. Orders received before 2:00pm (Mon-Fri) will be shipped on the same day (provided item is available in stock). You can pay with all major credit cards. On our side, we use PayPal to process all credit card transactions. But on your side, it will be like any regular purchase. You do not need to create a PayPal account. From the shopping cart, simply select "PayPal / Credit Card", then select "Pay with a credit or Visa debit card". Customer satisfaction guaranteed, or your money back. RCC Electronics is proudly Canadian. We have been selling the best test equipment since 1978. |
Measure minute voltage or temperature waveform by 16 bit resolution, isolated input
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Functions | No. of channels: 15, for voltage/temperature measurement (selectable for each channels) |
---|---|
Input connectors |
Voltage/thermocouple input: push button terminal Recommended wire diameter: single-wire φ 0.32 mm to φ 0.65 mm, stranded wire 0.08 to 0.32 mm2 (conductor wire diameter min. φ 0.12 mm), AWG 28 to 22 Input resistance: 1 MΩ Max. rated voltage to earth: 100 V AC, DC (with input isolated from the main unit, the max. voltage that can be applied between input channel and chassis and between input channels without damage) |
Voltage measurement ranges |
500 μV to 5 V/div, 9 ranges, full scale: 20 division * The AC instantaneous voltage waveform cannot be measured due to the slow sampling speed. Resolution: 1/1000 of measurement range (using 16-bit A/D converter) Accuracy: ±0.1 % f.s. (with digital filter ON, Zero position accuracy included) |
Temperature measurement range |
Reference junction compensation: Internal/ External (selectable) Thermocouple broken-wire detection: ON/OFF (selection applies to entire unit) Thermocouple type: K, J, E, T, N, R, S, B, WRe5-26 * For thermocouple measurement ranges, resolution, and accuracy, refer to the specifications table below |
Digital filter | 50 Hz, 60 Hz, or OFF |
Data refresh rate |
10 ms (with filter OFF, burn-out detection OFF) 20 ms (with filter OFF, burn-out detection ON) 500 ms (with filter ON, data refresh rate: Fast) 2 s (with filter ON, data refresh rate: Normal) |
Max. allowable input | 100 V DC (the max. voltage that can be applied across input pins without damage) |
Dimensions and mass | 119.5mm (4.70 in)W × 18.8mm (0.74 in)H × 184.8mm (7.28 in)D, 190 g (6.7 oz) |
Accessories | Ferrite clamp ×2 |