Call to speak with an agent: 1-800-668-6053
E-mail: sales@rcce.com
Welcome visitor you can login or create an account.
> Brand: HIOKI 8423 - HIOKI Memory HiLogger

8423 - HIOKI Memory HiLogger

8423 - HIOKI Memory HiLogger
8423 - HIOKI Memory HiLogger
Brand: HIOKI
Product Code: 8423
Availability: 2-4 Weeks
*** Click here to view manufacturer specifications ***
Video
Price: CAD 3,542.00
Qty:  
      

All products ship from Toronto, Canada by courier. Shipping is usually 1-10 days depending on your location in Canada. Shipping is free of charge. Orders received before 2:00pm (Mon-Fri) will be shipped on the same day (provided item is available in stock). 

You can pay with all major credit cards. On our side, we use PayPal to process all credit card transactions. But on your side, it will be like any regular purchase. You do not need to create a PayPal account. From the shopping cart, simply select "PayPal / Credit Card", then select "Pay with a credit or Visa debit card".

Customer satisfaction guaranteed, or your money back. RCC Electronics is proudly Canadian. We have been selling the best test equipment since 1978.

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

No. of connectable units Maximum 8 units (total 120 channels), Bundle 8 modules together to achieve a 120-channel system, Bundle 5 systems together to enable a maximum of 600 channels of simultaneous recording
Measurement parameters Model 8948 [No. of channels] 15 analog channels, isolated scanning method input (2 terminals: M3 screw type)
[Voltage measurement range] ±150 mV to ±100 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 100 VDC, between channels: 200 VDC, to earth: 600 VAC/DC
[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
Measurement parameters Model 8949 [No. of channels] 15 analog channels, isolated scanning method input (4 terminals: push-button type) (not isolated between channels at resistance temperature sensor & humidity sensor)
[Voltage measurement range] ±150 mV to ±60 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 60 VDC, between channels: 120 VDC, to earth: 600 VAC/DC
[Temperature range] −200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
[Resistance temperature sensor range] −200˚C to 800˚C, (Pt 100, JPt 100), Max. resolution 0.01˚C
[Humidity] 5.0 to 95.0% rh, (use with optional sensor 9701), resolution 0.1% rh
Measurement parameters Model 8996 [No. of channels] 15 channels, digital/pulse input (2 terminals: M3 screw type, CH1-5, CH6-10, CH11-15 are common GND, No-voltage ‘a’ contact, open collector or voltage input)
[Totalized pulses] 0 to 1000M pulse, Max. resolution 1 pulse
[Rotation count] 0 to 5000/n (r/s), Resolution 1/n (r/s) *n = pulses per rotation (1 to 1,000)
[Digital input] Record ON/OFF digital signal per interval
[Max. allowable input] 50 VDC, between channels: 33 VACrms or 70 VDC, to earth: 600 VAC/DC, (Upper limit voltage that does not cause damage when applied between CH1-5, CH6-10, CH11-15 each channel and chassis, and between each UNITs)
Recording intervals 10 ms to 1 hr, 19 ranges (5s to 1hr when combined with humidity measurement), Dual sampling: Recording intervals can be specified for every input module (high-speed and low-speed)
Function Measurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the Alarm unit 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function
Interface LAN: supports 100Base-TX, USB: Ver 2.0, mini-B receptacle, CF card slot
Power supply Using the AC adapter 9418-15 (100 to 240 V, 50/60 Hz), 55 VA Max. (include AC adapter), 20 VA Max. (main unit only) (when connected with 8 units), 
External DC Power: 9.6 V to 15.6 VDC, 20 VA Max. (when connected with 8 units) (Please contact HIOKI for connection cord)
Dimensions and mass 67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
Accessories Quick start manual × 1, Instruction manual × 1, AC adapter 9418-15 × 1, USB cable × 1, CD-R (data collection software “Logger Utility”) × 1, Connector cover × 1, Ferrite clamp × 1, Connection plate × 1

■ Combination status with LabVIEW or MATLAB script

Compatible models LabVIEW MATLAB script
8423 OK N/A

 

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Tags: