HIOKI PQ3198A: Class A Power Quality Analysis for Modern Electrical Systems

Posted by Billy 17/11/2026 0 Comment(s)
HIOKI · PRODUCT NEWS

Short answer: The new HIOKI PQ3198A combines IEC 61000-4-30:2025 Edition 4 Class A power-quality measurement with long-term trends and event waveforms of up to 11.2 seconds. It is designed to help engineers document disturbances and examine the electrical conditions surrounding an event.

  • Review event waveforms alongside voltage, current and power trends.
  • Capture transient voltage at 2 MS/s and up to ±6 kV peak.
  • Confirm the measurement range, safety category and sensors before connecting.

Power-quality investigations often start with a voltage dip, interruption or equipment trip. Determining what happened next requires context: the electrical load, operating conditions and waveform before and after the event.

Announced by HIOKI on November 16, 2026, the PQ3198A is intended for power-quality monitoring and troubleshooting across facilities, distribution systems and power-conversion equipment. Its data can support investigation; an event record alone does not prove the cause.

 

What does Class A measurement mean?

HIOKI states that the PQ3198A complies with IEC 61000-4-30:2025 Edition 4, Class A. The standard defines measurement methods and requirements, including timing, accuracy and aggregation, to support consistent power-quality results. Check the applicable edition, measurement setup and reporting requirements for the particular project.

Specification Manufacturer information What to confirm
Power-quality standard IEC 61000-4-30:2025 Ed. 4, Class A Required methods and reporting for the project
Inputs Four voltage and four current channels Wiring arrangement, sensors and leads
Event waveform Up to 11.2 seconds Trigger settings and event context
Transient voltage 2 MS/s, up to ±6 kV peak Applicable measurement conditions
Voltage and safety 1000 V CAT III / 600 V CAT IV; RMS measurement up to 600 V at launch Safety category is not the RMS measurement range
 

See the conditions around a disturbance

The PQ3198A detects conditions including dips, swells, interruptions, transient voltage, inrush current and harmonics. HIOKI specifies up to 11.2 seconds of event waveform data: one second before the event, a 200 ms event and ten seconds afterward. Review the waveform together with longer-term trends and the operating log.

A change in load current around a dip can help focus an investigation, but it is not conclusive evidence of the source. Compare the timing with switching, equipment operation and other measurement points before drawing conclusions.

 

Capture short transient voltage events

Some events are too brief to interpret from trend data alone. HIOKI specifies transient-voltage sampling at 2 MS/s and a transient measurement capability up to ±6 kV peak. These are transient specifications, not a continuous RMS voltage rating. Select leads and measurement points that meet the instrument and installation requirements.

 

Measure AC and DC in power-conversion applications

The instrument has four voltage and four current inputs. HIOKI states that the fourth voltage channel is electrically isolated from the first three, enabling suitable combinations such as three-phase AC and DC measurement. This is useful context for UPS, solar and charging applications when configured for the actual circuits.

The safety rating is 1000 V CAT III / 600 V CAT IV. HIOKI also states that the maximum RMS voltage measurement range at launch is 600 V. These numbers describe different limits; neither replaces the need to check all instrument, lead and sensor ratings.

 

From field data to reporting

HIOKI's PQ ONE software is available as a free download for the PQ3198A. According to HIOKI, it can load multiple datasets, support statistical analysis and standards evaluation, and generate reports. Verify the current software version and project-specific reporting requirements.

Potential applications include UPS and generator commissioning, factory and commercial-facility monitoring, renewable-energy and EV-charging installations, and electrical-distribution troubleshooting.

 

Availability and configuration in Canada

HIOKI's November 16, 2026 announcement states that the PQ3198A is available for order, with first shipments scheduled for late February 2027. Canadian availability, pricing, supported current sensors and accessories should be confirmed with RCC Electronics. The existing HIOKI PQ3198 is a different model; do not assume its listing or specifications describe the PQ3198A.

 

FAQ: HIOKI PQ3198A

What standard does the PQ3198A support?
HIOKI specifies IEC 61000-4-30:2025 Edition 4, Class A.

How much event waveform data can it record?
HIOKI specifies up to 11.2 seconds, including the pre-event and post-event portions described above.

Does 1000 V CAT III mean it measures 1000 V RMS?
No. The measurement category is a safety rating. HIOKI states the maximum RMS voltage measurement range at launch is 600 V.

Can it measure AC and DC together?
HIOKI describes configurations such as three-phase AC and DC using its isolated fourth voltage channel. Confirm wiring and ratings for the specific application.

Is the PQ3198A the same as the PQ3198?
No. They are different model designations. Check the current documentation and configuration for the exact model.

 

Planning a power-quality investigation?

Contact RCC Electronics for PQ3198A availability and help reviewing the required sensors and leads.

 
Explore HIOKI Power Quality AnalyzersContact RCC Electronics

* Based on HIOKI's November 16, 2026 announcement. Specifications, shipping schedules and supported accessories may change; confirm current documentation and availability before selection.