Call to speak with an agent: 1-800-668-6053
Alternatively, press "Contact Us" below
Proudly Canadian since 1978
Welcome visitor you can login or create an account.
RCC Electronics ISO Certification
Power Measurement & Power Quality PW3360-21 - HIOKI Power Demand Analyzer (With Harmonics Function)

PW3360-21 - HIOKI Power Demand Analyzer (With Harmonics Function)

PW3360-21 - HIOKI Power Demand Analyzer (With Harmonics Function)
PW3360-21 - HIOKI Power Demand Analyzer (With Harmonics Function)
Brand: HIOKI
Product Code: PW3360-21
Availability: 2-4 Weeks
*** Click here to view manufacturer specifications ***
Video
Price: CAD 2,466.80
Qty:  
      

All products ship from Toronto, Canada by courier. Shipping is usually 1-10 days depending on your location in Canada. Shipping is free of charge. Orders received before 2:00pm (Mon-Fri) will be shipped on the same day (provided item is available in stock). 

You can pay with all major credit cards. On our side, we use PayPal to process all credit card transactions. But on your side, it will be like any regular purchase. You do not need to create a PayPal account. From the shopping cart, simply select "PayPal / Credit Card", then select "Pay with a credit or Visa debit card".

Customer satisfaction guaranteed, or your money back. RCC Electronics is proudly Canadian. We have been selling the best test equipment since 1978.

 

HIOKI's Newest Compact Energy Analyzer
  • Supports single to three-phase, 4-wire circuits
  • Measure up to 780V with a 1000V display range
  • Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)
  • Broadly applicable for many jobs, including leakage current measurement (An optional clamp-on leakage sensor supports measurements as low as 50 mA)
  • Store months of data on SD cards
  • The QUICK SET function guides you in making the right connections
Note: Optional current sensor is necessary to measure current or power parameters. To storage measurement data, use only the guaranteed SD cards sold by HIOKI
Basic specifications (Accuracy guaranteed for 1 year)
Measurement line & number of circuits Single-phase 2-wires(3 circuits), Three-phases 3-wires , Three-phases 3-wires , and Three-phases 4-wires (1 circuit), Current only: 1 to 3 channels, 50/60 Hz
Measurement items Voltage/current RMS, voltage/current fundamental wave value, voltage /current fundamental wave phase angle, frequency, voltage/current waveform peak (absolute value), active/reactive/ apparent power, power factor (with lag/lead display) or displacement power factor (with lag/ lead display), active energy (consumption, regeneration), reactive energy (consumption, regeneration), electricity rate display (by means of planned future function update), active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
Voltage ranges 600 V AC (single range)
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (LEAK CLAMP ON SENSOR only)
Power ranges 300.00 W to 9.0000 MW
(Depends on voltage/current combination and measured line type)
Basic accuracy AC Voltage : ±0.3% rdg. ±0.1% f.s
AC Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
Clamp-On Sensor 9661 accuracy: ±0.3% rdg. ±0.01% f.s. (Accuracy depends on clamp sensor)
Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destination SD Card, internal memory (capacity: approx. 320 KB)
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selects
Save items Measurement save: Average only / all (average, maximum, minimum)
Screen copy: The minimum interval time for saving screen copies is 5 min.
Interfaces [LAN] 10BASE-T/100BASE-TX IEEE802.3 Compliance
[USB] USB Ver 2.0, Windows 7 (32/64bit) /Vista (32bit) /XP
Functions Quick Set, Backup, Key Lock, Pulse Input, Pulse Output
Power supply AC ADAPTER Z1006: (12 V, 1.25 A), Rated supply voltage 100 VAC to 240 VAC, Rated power supply frequency 50/60 Hz
BATTERY PACK 9459: (Ni-MH DC7.2 V 2700 mAh)
Dimensions, mass 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in) W × 100 mm (3.94 in) H × 68 mm (2.68 in) D, 830 g (29.3 oz) with PW9002
Accessories VOLTAGE CORD L9438-53 ×1 set, AC ADAPTER Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color spiral tubes ×1 set: red, yellow, blue/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5

 