SIGLENT EA0210 External Attenuator
The EA0210 is a 2:1 external attenuator for the SIGLENT SAP1000H high-voltage differential active probe. It increases the probe input range when used with a compatible instrument.
Key Information
-
2:1 attenuation; 1 GHz system bandwidth with SAP1000H as specified in the probe manual.
-
SAP1000H plus EA0210 has a specified input dynamic range of ±60 V; maximum input voltage with respect to ground is ±90 V.
-
The oscilloscope does not automatically detect the attenuator: select EA0210 in the active-probe External Attenuator menu and select NC after removal.
Compatibility and Safety
For the SIGLENT SAP1000H probe. Consult the probe manual for detailed ratings, frequency derating, measurement setup and safety precautions. The attenuator is not a standalone probe.