> Brand: DV Power CVA500 - DV Power Current and Voltage Transformer Analyzer

CVA500 - DV Power Current and Voltage Transformer Analyzer

CVA500 - DV Power Current and Voltage Transformer Analyzer
CVA500 - DV Power Current and Voltage Transformer Analyzer
Brand: DV POWER
Product Code: CVA500
Availability: 2-4 Weeks
*** Click here to view manufacturer specifications ***

Current and Voltage Transformer Analyzer CVA500 is DV Power instrument specially made for testing current transformers (CT). It can perform multiple tests – turns ratio, saturation (knee point), burden, demagnetization, winding resistance, and insulation resistance. Besides these tests, CVA500 calculates ratio and phase errors for 8 different primary currents and 4 different burdens. Based on obtained ratio and phase error values, CVA500 automatically determines if CT is within its specified accuracy class. For IEC-based measurement type CTs, instrument security factor (FS) is calculated, while accuracy limit factor (ALF) is calculated for IEC-based protection type CTs. In both cases, composite error is measured, and automatic pass/fail assessment is made. For IEEE-based protection type CTs, a secondary terminal voltage (Vb) is provided and automatically assessed as either pass or fail.

CVA500 can be connected to all CT measurement terminals including primary side, up to 5 taps on secondary side, and burden, at once. An internal sophisticated relay matrix enables performing ratio, saturation, burden, and winding resistance measurements in all 5 taps automatically, without any cable reconnection. Insulation resistance can be measured between any parts – primary to ground, secondary to ground, primary to secondary, and secondary to other core(s) in case of multi-core type CTs.

CVA500 is a very powerful device. It can output up to 2000 V AC (at rated frequency, 50 or 60 Hz) for saturation (knee point) test, and 500 V DC or 1000 V DC for insulation resistance test.

CVA500 can also be used for testing inductive voltage transformers (VT/PT) and capacitive voltage transformers (CVT). A wide resistance measurement range allows measuring winding resistance of VTs primary winding, in addition to secondary winding. Operating burden is measured using the burden rated voltage (up to 250 V AC). For turns ratio test, CVA500 can output maximum voltage of 2 kV AC, which ensures reliable and accurate results even on large CVTs. Insulation can be tested between any parts – primary to ground, secondary to ground, primary to secondary, and secondary to other core(s) in case of multi-core type VTs/CVTs.