For Motor and Inverter Efficiency Analysis. Multi-channel measurement applications using SiC/GaN semiconductors from automobile electrification, smart grids and reactors to renewable energy supply sources.
Contact RCC Electronics for Canadian availability, configuration guidance and a formal quotation.
| Main functions | Insulation resistance test; Break Down Detect function (BDD); Contact check function |
|---|---|
| Output specifications | Output voltage : 25 V to 500 V, Setting resolution 1 V; Charging current ; (Current limit function) : 50 µA to 50 mA*1*2*3, Minimum setting resolution 10 μA; Short-circuit current : 60 mA or less; Discharge current : 40 mA or greater; ; *1: Constraints involving the output generator will result in an error, making measurement impossible, if a capacitive load of approximately 50 μF or greater is connected while using a current limit setting of 5.1 mA or greater.; *2: When using a current limit setting of 5.1 mA or greater, measurement will be forcibly stopped if the output voltage is not at least 20 V at 200 ms after the start of measurement. Measurement will be possible 1 s after forcibly stopped.; *3: If the set current limit value is from 5.1 mA to 50.0 mA, the current will be limited to 5 mA after the output voltage reaches the set voltage. |
| Measurement specifications | Resistance value display range : 0.050 MΩ to 9999 MΩ; Resistance range : 2 MΩ, 20 MΩ, 200 MΩ, 2000 MΩ, AUTO |
| Basic specifications | ±1.5% rdg.±2 dgt.; 25 V ≤ V < 100 V [0.05 MΩ to 2 MΩ],; 100 V ≤ V ≤ 500 V [0.2 MΩ to 20 MΩ] |
| Time specifications | Test time : 0.050 s to 999.999 s, OFF; Comparator delay time : 0.001 s to 999.999 s, AUTO; Display update speed : 1 PLC; Sampling time : 1 PLC to 100 PLC |
| Memory functions | Panel save function : Saves up to 15 sets of measurement conditions; Measured value memory function : Saves up to 999 measured values in the instrument's internal memory |
| Judgment functions | Test modes : Continuous test, PASS STOP, FAIL STOP; Comparator function : ; UPPER_FAIL : Measured value > upper limit value; PASS : Upper limit value ≥ measured value ≥ lower limit value; LOWER_FAIL : Measured value < lower limit value |
| Various functions | Break Down Detect function (BDD) : Detecting minuscule insulation defects caused by contamination; Contact check function : 2-terminal capacitance measurement method; Automatic data output function : Automatic output of measurement results via communication interface after completion of test; Command monitor function : Screen display of commands being sent and received; External I/O monitor function : Screen display of output signal ON/OFF and input signal status; Analog output function : Converts measured values to 0 to 4 V DC and outputs |
| Interfaces | USB, LAN, RS-232C, EXT. I/O |
| Power supply | 100 V to 240 V AC |
| Power consumption | Approx. 20 VA*4; ; *4: Power supply conditions are 220 V supply voltage, 50, 60 Hz supply frequency, 200 V test voltage, 2 mA current limit, and load (1 GΩ resistor and 0.1 μF capacitor connected in parallel). |
| Maximum rated power | 100 VA |
| Dimensions and mass | Approx. 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D (excluding protruding parts), Approx. 2.8 kg (98.8 oz) |