Call to speak with an agent: 1-800-668-6053
Alternatively, press "Contact Us" below
Proudly Canadian since 1978
Welcome visitor you can login or create an account.
RCC Electronics ISO Certification
DT4282 - HIOKI Digital Multimeter

DT4282 - HIOKI Digital Multimeter

DT4282 - HIOKI Digital Multimeter
DT4282 - HIOKI Digital Multimeter
Brand: HIOKI
Product Code: DT4282
Availability: In Stock
*** Click here to view manufacturer specifications ***
Video
Price: CAD 803.60
Qty:  
      

All products ship from Toronto, Canada by courier. Shipping is usually 1-10 days depending on your location in Canada. Shipping is free of charge. Orders received before 2:00pm (Mon-Fri) will be shipped on the same day (provided item is available in stock). 

You can pay with all major credit cards. On our side, we use PayPal to process all credit card transactions. But on your side, it will be like any regular purchase. You do not need to create a PayPal account. From the shopping cart, simply select "PayPal / Credit Card", then select "Pay with a credit or Visa debit card".

Customer satisfaction guaranteed, or your money back. RCC Electronics is proudly Canadian. We have been selling the best test equipment since 1978.

 

Speedy Performance of Professional Testing - Two Models Provide High Accuracy and Fast Response

  • 60,000 count, 5-digit display, high-resolution measurements
  • ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Includes multiple measurement functions such as DC+ACV, temperature, capacitance, and frequency
  • Includes terminal shutter mechanism for accident prevention (prevents erroneous test lead insertion)
  • Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention)
  • USB communications function supports PC measurements (optional)
  • Broad -15 (5°F) to 55°C (131°F) operating temperature range
Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
Basic specifications (Accuracy guaranteed for 1 year)
  DT4281 DT4282
DC Voltage 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC Voltage
45 to 65 Hz
60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.3 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC Voltage
45 to 65 Hz
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.4 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)
Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC Current 600.00 μA to 600.00 mA, 4 ranges 600.00 μA to 10.000 A, 6 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC Current
45 to 65 Hz
600.00 μA to 600.00 mA, 4 ranges 600.00 μA to 10.000 A, 6 ranges
Basic accuracy: ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current
(use with the Clamp on probe)
45 to 1k Hz
10.00 A to 1000 A, 7 ranges Not available
Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt.
(True RMS, crest factor 3)
Not available
Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement:
Signal width 1 msec or more (single), 250 μsec or more (repeated)
C (capacitance) 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less,
Threshold of forward voltage: 0.15 V to 3 V, seven stages
Frequency AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.02 % rdg. ±3 dgt.
dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
Temperature -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) (use with optional probe DT4910)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.3 % rdg. ±3 °C
Other functions Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
Display Main and Sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours
Dimensions, mass 93 mm (3.66 in)W × 197 mm (7.76 in)H× 53 mm (2.09 in)D, 650 g (22.9 oz) (with test leads holder and batteries)
Supplied accessories TEST LEAD L9207-10 ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4

 